Cape Cod, Salt Box, Modified A-Frame, Bungalow

Homes with a second “half-story” pose unique challenges for proper air sealing and insulation. Prone to ice dams and other issues, the SCES team pays story-and-a-half homes special attention. We are careful to maintain adequate air sealing, insulation, and ventilation at every step.

Anatomy of a Story-and-a-Half Home

All story and a half homes have some variation of the following components:

Flat or “Collar” Attic

In this type of attic, the flat ceiling of the second story forms the floor of a small attic space near the peak of the home. Some homes have a cathedral or vaulted ceiling in lieu of a collar attic.

Knee Walls

Knee walls are the short, “knee height” walls along the perimeter of the room. They separate the finished space from the often unfinished side attics.

Slant Walls

These are the slanted wall portion of the room. These walls follow the underside of the roof rafters from the top of the knee wall to the bottom of the collar attic.

Side Attics

Side attics form the ceiling of the story below, and offer great storage spaces for seasonal items.

Your planned use of the space determines how best to insulate and air seal your home. There are two basic arrangements of the story-and-a-half home:

Arrangement One: Fully Conditioned Roofline (Conditioned Side Attics)

Insulating between the rafters of a story-and-a-half home, from the eave to the peak, brings the entire upper floor into the “conditioned space” of the home. That means that the side attics are kept at or near the temperature of the rest of the home. The challenge with this arrangement is ensuring adequate insulation and ventilation are provided in a very small space in the rafters (often as little as 3½ or 5½ inches of space).

The SCES team has a few suggested treatments to overcome this

 challenge:

Dense Pack the Slants

Insulation can often be added to the slant walls by densely packing in a loose fill insulation material.

Ventilate the Roof Deck

Ventilation can often be improved by installing or propping open ventilation chutes. Proper “high side” ventilation should also be present near the peak, which requires that roof vents (or a continuous ridge vent) be cut into the roof above the collar attic.

Add Foam Board Insulation to Side Attic Ceilings

Insulation can be added in the side attic areas by attaching rigid foam board insulation to the underside of the rafters.

Air Seal the Exterior Wall Top Plates with 2-Part Foam

The connection between the rafters and the exterior walls of the floor below should be foam sealed to reduce air infiltration.

Arrangement Two: Unconditioned Side Attics

In this arrangement, side attics are “unconditioned,” meaning the air in them is often vented to the outdoor air. The extreme temperatures swings in the side attics from season to season lead to temperature swings in the upper floor rooms as well. These rooms are freezing cold in winter and stiflingly hot in summer. Homeowners with unconditioned side attics often convert this space to a fully conditioned roofline (like in the first arrangement).

SCES has a few additional suggestions for improvements, including:

Add Ventilation to Side Attics

Adding ventilation chutes in each rafter bay allows cool air to enter the side attic. Similarly, inserting vent chutes into the slant walls allows air to flow properly (up from the eaves, through the side attic, up the slants, and out through a ventilated collar attic). The roof must have proper “high side” ventilation near the peak, which often requires cutting roof vents (or a continuous ridge vent) into the roof above the collar attic.

Fully Insulate Knee Walls

Basic, unfaced fiberglass batts installed in the knee wall do not sufficiently isolate the side attic from the conditioned interior space. The backside of the knee walls should be covered with rigid foam board insulation or with a vapor-permeable building paper (like Tyvek® or Weathermate®).  Using building paper and foam board prevents the unconditioned air, whether it’s cold winter air or hot summer air, from permeating the bare fiberglass batts.

 

Install Blocking Below the Knee Wall

The floor joists below knee walls are an often overlooked component of your home’s thermal envelope. Our team installs sealed blocking between each joist bay to prevent conditioned air from escaping.

Fully Insulate Side Attic Floors

If they are not being used for storage, side attic floors can be piled high with loose-fill insulation. Thermal resistance of R-60 is recommended for the Wisconsin/Twin Cities Metro Area climate zone. If the side attic has a floor and will be used for storage, the joist bays can be densely packed with insulation. Once dense-packed, foam board insulation can be laid on top of floor decking to increase the R-Value of the storage floor.

Air Seal the Exterior Wall Top Plates with 2-Part Foam

The connection between the rafters and the exterior walls of the floor below should be foam sealed to reduce air infiltration.

No matter the arrangement of your one-and-a-half story home, the SCES team is ready to work to make sure your home is working as efficiently and cost-effectively as possible. If you’re ready for lower energy bills and improved home comfort, get in touch with us to set up an evaluation.

Contact UsEnergy Assessments for $450 or less

Schedule your FREE Home Estimate

Testimonials

Susan S., Hudson, WI

Dear Pete,

I had an audit by St. Croix Energy Solutions. You were prompt, professional and had very valid and reasonable suggestions. I felt no undue pressure from you at all! Your suggestions included issues I suspected and some I had not.

The amount of information I got in the audit was worth 10 times what I paid.

I did as St. Croix Energy Solutions suggested and I can feel a difference in the house. It is 7 below today and quite tolerable in the rooms that were not tolerable before. The crew that did the work was really good. The... (read more)